1.
Photomed Laser Surg ; 36(11): 621-628, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30260736

RESUMO

OBJECTIVES: The aim of the present study was to investigate differences in the amount of dentin microcracking caused by the use of a 970-nm diode laser with different parameters for endodontic disinfection procedures. MATERIALS AND METHODS: Forty dental roots underwent mechanical endodontic preparation in a standardized manner. Each sample was randomly allocated to 4 groups receiving constant or interval laser irradiation time, calcium hydroxide disinfection, or a control group, with 10 samples per group. Transmission microscopy of all samples was performed at T0, before preparation; T1, immediately after endodontic preparation; and T2, after laser application in the laser groups and after 1 week of storage in the control and calcium hydroxide groups. The microcracks at each measurement point were color labeled, layered, and compared. RESULTS: No significant differences were noted at T0 and T1 (p > 0.05). Statistically significant differences in the overall amount of microcracking were observed between the constant laser group and all other groups at T2 (p < 0.05). There were no statistically significant differences between the interval laser group, the calcium hydroxide group, and the control group at T2 in relation to the overall amount of microcracking (p > 0.05). When the root sections were analyzed separately, the coronal section did not show any statistically significant differences between the constant laser and interval laser groups (p > 0.05). The middle and apical root sections in the constant laser group showed the significantly largest amount of crack formation in comparison with the other groups (p < 0.05). The statistically significantly smallest amount of crack formation was observed in the apical third for all groups (p < 0.05). CONCLUSIONS: Clinically proposed laser protocol seems to be able to prevent side effects to the tissue, such as microcracks of the root canal dentine.


Assuntos
Cavidade Pulpar/efeitos da radiação , Dentina/efeitos da radiação , Desinfecção/métodos , Lasers Semicondutores , Preparo de Canal Radicular/métodos , Fraturas dos Dentes/etiologia , Raiz Dentária/efeitos da radiação , Humanos , Técnicas In Vitro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...